Peel Bridge Refurbishment 16 March 2011 Repainting of the Fenella Bridge has been delayed by one week to give local painting contractors the opportunity to see if they can meet the technical requirements of the work, be price competitive and still meet the time schedule to enable the bridge to reopen before the Easter weekend. Following representations made to political Members of the Department by a local painting contractor the decision was made to give the local contractor, and others, a short period of time to tender for the work. The original paint coating on the bridge was specified to last 10 years to first maintenance; however, the paint system had already started to fail after only 5 years. The Department, which is currently in a dispute with the designer over the bridge performance, decided to take the opportunity to re-paint the bridge whilst it is on land for design modifications to the turning mechanism. Initially, the Department took the view that there were no competent contractors for this type of work on island following a tender exercise carried out for the re-painting of Poortown Quarry, which failed to realise any local tenders and therefore intended to award the contract to an off island specialist that has carried out similar work on the island on many occasions. However, late last week it came to light that a local contractor felt that he was able to meet the specification requirements and wanted to submit a price. This firm and some others have now been afforded this opportunity. The work to clean and paint the bridge is of a highly specialised nature and requires the application of a high quality epoxy paint system that has to be applied in humidity and temperature controlled environment. The paint specification has been designed to withstand the severe exposure and marine conditions at the harbour. The paint system will be applied in four coats using a combination of two pack epoxy products for the primer coats and a two component acrylic polyurethane finish coats that will give a minimum overall dry film thickness (DFT) of 345 microns. The paint system is spray applied by skilled operatives and requires the use of suitable respiratory equipment. Following its previous experience with prematurely failed paint work the Department is keen to ensure that this specialist product, which requires specialist preparation of the surface in addition to the controlled environmental conditions, is applied with the best chance of succeeding. The paint system will be provided with a 10 year guarantee by the paint manufacturer and the workmanship will also need to be backed by a 10 year guarantee by the painting contractor. Further technical information: Mr G Saunders, Construction Manager Tel: 850048 More stories >>>
|